GE SLE 2000 HFO: Neonatal Ventilator with High-Frequency Oscillation for Improved Respiratory Support. Learn More! SLE3600 Infosys Nitric Oxide Therapy:
- The SLE Infosys Inhaled Nitric Oxide delivery system delivers low-concentration NO therapy with typical concentrations being in the range of 2-80 ppm. The Infosys is usable with any constant-flow ventilator and is an ideal add-on for the SLE2000, SLE2000 HFO, SLE4000, and SLE5000 ventilators. With user-settable alarms for high? and low concentrations, the unit automatically reduces therapy if an alarm is triggered
- Monitors both NO and NO2
- Alarms for both NO and NO2
- Long-life cells
- Internal printer
- Simple calibration
- Internal battery back-up
- Can be used on any constant-flow ventilator
Air Compressor:
- A free-standing air compressor is also available for use with the SLE2000 HFO. Please see your local distributor for further details
Screen Displays:
- The high-resolution LCD (Liquid Crystal Display) is used to show waveforms, including high frequency modes
SLE2000 HFO with Single-use Circuits:
- Stand-mounted ventilator? complete with a servo-? controlled humidifier -? ? typically a Fisher & Paykel? (or equivalent), air and? ? Oxygen hoses and manual? (3 single-use patient circuits? included for user start-up).? Includes 2 pin European- style plug.
SLE2000 HFO with Reusable Circuit:
- Stand-mounted ventilator? complete with a servo-? controlled humidifier -? ? typically a Fisher & Paykel (or equivalent), air and Oxygen? hoses and manual (reusable? patient circuit included for? user start-up). Includes 2 pin? European-style plug
Product Details:
- Exceptional pneumatic performance
- The operation of the unique valveless system eliminates the need for exhalation valves, diaphragms etc. meaning less to clean and easier, safer assembly
- The simple patient circuit (suitable for all modes of ventilation), together with the valveless system, reduces problems of resistance and compliance
- The principle of operation of the valveless system reduces inadvertent PEEP, and aids in the total clearance of expired gases
- Automatic gas flow adjustment
- Ability to maintain pressure waveforms at all rates
- Sensitive airway pressure trigger
- Comprehensive alarm system
- Built in oxygen analyser with continuous digital readout
- Clear and easily set controls, including tamper-proof pneumatic controls
- High pressure relief, on alarm
- Exhaled gases can be filtered
- Optional auxiliary blended flow outlet
- Choice of square or slow rise time, switch selectable
- Ability to entrain other gases e.g. Nitric Oxide
Indicators:
- System Fail: Indicates main processor system fail
- BPM Display: Breaths per minute
- Insp Time Display: Inspiratory time
- IE Ratio: Inspiration to expiration ratio
- Trigger Back up: Indicates a machine delivered breath ifpatient fails to trigger ventilator duringuser-controlled back-up time window
- CPAP/PEEP: Indicator for set up of pressures
- Oscillator Gauge: Indicator for set up of pressures
- Inspiratory Gauge: Indicator for set up of pressures
Alarms:
- HFO Fail: Motor drive to oscillator failure
- Fan Fail: Motor fan failure
- High/Cycle/Low: User adjusted, visual and 7 Hz, intermittent audible
- Block-Leak: Of fresh gas – visual and? continuous audible
- Mute: 60 seconds
- Reset: Resets all alarms except system fail, HFO and fan fail
- Loss of Mains: Battery powered, audible
- Loss of Air or Oxygen: Pneumatic, audible from blender