Siemens Maquet SERVO-s Features
The Getinge Maquet Servo-s? ventilator features a wide range of ventilation modes that can be tailored to specific clinical situations. The Servo-s has a large intuitive user interface that provides valuable decision-support information. This Maquet ventilator has been designed for both shelf mounting and in-hospital transport with a mobile cart. It supports invasive and non-invasive ventilation with leakage compensation for non-invasive ventilation modes for all patient types. If you’re looking for a similar model try the Servo-i ventilator.
- Invasive and non-invasive ventilation with leakage compensation.
- User-friendly user-interface.
- Rotary dial and direct access knobs for navigation.
- Designed for shelf mounting or intrahospital transport with a mobile cart.
- Quick inspiratory flow controller allows for reduced work of patient breathing.
Siemens Maquet SERVO-s Specifications
Dimensions
- Height: 20.5? (52 cm)
- Width: 15? (38 cm)
- Depth: 11.8? (30 cm)
- Weight: 44 lbs (20 kg)
Parameter Settings
- Inspiratory tidal volume (ml): 100? 2000
- Inspiratory minute volume (l/min): 0.5? 60
- Apnea, time to alarm (s): 15? 45
- PC/PS above PEEP (cmH2O): 0?(120 – PEEP)
- PC/PS above PEEP in NIV (cmH2O): 0?(62 – PEEP)
- PEEP (cmH2O): 0? 50
- PEEP in NIV (cmH2O): 2? 20
- CMV frequency (breaths/min): 4? 100
- SIMV frequency (breaths/min): 1? 60
- Breath cycle time, SIMV (s): 1? 15
- PHigh?(cmH20): (PEEP + 1)?50
- THigh?(s): 0.2?30
- TPEEP?(s): 0.1?10
- O2 concentration (%): 21?100
- I: E ratio: 1:10?4:1
- TInsp?(s): 0.1?5
- TPause (% of breath cycle time): 0? 30
- Flow trigger sensitivity level: 0? 10
- Press. trigg sensitivity (cmH2O): -20?0
- Insp. rise time (% of breath cycle time): 0? 20
- Insp. rise time (s): 0? 0.4
- End inspiration (% of peak flow): 1? 70
- End inspiration in NIV (% of peak flow): 10? 70
- Oxygen Breaths: 100% for 1 minute
- Start Breath: Initiation of 1 breath (In SIMV mode initiation of 1 mandatory breath)
- Pause Hold: Insp. or exp (0? 30 seconds)
Screen
- Type: TFT-LCD module
- Size: 12.1? (31 cm) diagonal
- Viewing area: 9.7? x 7.3? (24.6 x 18.5 cm)
Backup Parameter Settings
- Inspiratory Tidal Volume (ml): 100? 2000
- PC Above PEEP (cmH2O): 5?(120 – PEEP)
- PC above PEEP in NIV (cmH2 O): 5?(62 – PEEP)
- CMV frequency (breaths/min): 4? 100
- I: E ratio: 1:10?4:1
- TInsp?(s): 0.1?5
Power
- Power Supply, Automatic Range Selection: 100?120 V AC ? 10%, 50?60 Hz, or 220?240 V AC ? 10%, 50?60 Hz
- External 12 V DC: 12.0 V? 15.0 V DC, 10 A
- Battery Capacity: 2 rechargeable battery modules 12 V, 5 A, 3.5 Ah each
- Battery Backup Time: At least 1 h with 2 fully charged batteries
- Battery Recharge Time: Approximately 3h/battery
- Max Power Consumption: At 100?120 V: 2 A, 190 VA, 140 W; At 220?240 V: 1 A, 190 VA, 140 W
Controlled Invasive Ventilation
- PC (Pressure Control)
- VC (Volume Control)
- PRVC (Pressure Regulated Volume Control)
- Can be configured with alternative flow patterns: VC with flow adaptation; VC without flow adaptation; VC with decelerating flow
Supported Invasive Ventilation
- PS/CPAP (Pressure Support / Continuous Positive Airway Pressure)
Combined Invasive Ventilation
- SIMV (PC) + PS (Synchronized Intermittent Mandatory Ventilation)
- SIMV (VC) + PS
- SIMV (PRVC) + PS
- Bi-Vent/APRV (Airway Pressure Release Ventilation)
Non-Invasive Ventilation
- Leakage Compensation Level: Inspiratory, up to 200 l/min; Expiratory, up to 65 l/ min
- Leakage Overrange Detection: Automatic
- Disconnect Detection: Automatic
- Disconnect flow: Low; High; Disabled; Configurable 7.5 l/min; 40 l/min;
- Deactivates disconnect detection
- Connect Detection: Manual, or automatic via bias flow